Normally Open vs Normally Closed Micro Switch
The difference between a normally open (NO) and a normally closed (NC) micro switch, how to tell them apart with a multimeter, and which contact to specify for your circuit.
The short answer
A normally open micro switch keeps its contacts apart when the actuator is at rest, so the circuit is broken until the switch is pressed. A normally closed micro switch keeps its contacts together at rest, so the circuit is complete until the switch is pressed. "Normally" always refers to the unactuated state with no external force applied — not to the state of the machine the switch is mounted on.
State table
| State | Normally open (NO) | Normally closed (NC) |
|---|---|---|
| Actuator released (at rest) | Open circuit — no continuity | Closed circuit — continuity |
| Actuator pressed | Closed circuit — continuity | Open circuit — no continuity |
| Actuator released again | Returns to open | Returns to closed |
The two behave as exact opposites, which is why a three-terminal SPDT micro switch can supply both at once: the same mechanical movement opens one contact and closes the other.
How to tell NO from NC with a multimeter
- Disconnect the switch from the circuit and set the meter to continuity or resistance.
- Leave the actuator untouched — do not press it.
- Probe the middle terminal against each of the outer terminals.
- The pair that beeps (or reads close to zero ohms) is COM and NC. The pair that reads open is COM and NO.
- Press the actuator and repeat: the readings should swap, which confirms the switch is working.
Do not rely on the physical position of the pins. Terminal order differs between series, and a two-terminal switch has no common to compare against — check its datasheet instead.
Which one should you specify?
The decision is about failure behaviour, not convenience. Choose the contact that produces the safe state when the mechanism fails, the wire breaks or the power is lost.
Use normally closed when
- The circuit must fail safe — a broken wire should stop the machine, not let it run. Safety interlocks, emergency stops and machine guards are wired NC for this reason.
- The switch detects the end of travel and must stop a motor when it is reached.
- You want the controller to notice a disconnected sensor: an NC loop that suddenly reads open is a fault, whereas a broken NO loop looks identical to "not actuated".
Use normally open when
- The action should start something — a start button, a pedal or a presence sensor.
- The signal is an event rather than a condition, such as counting parts as they pass a lever.
- Idle power consumption matters: an NO contact draws nothing until it closes.
Use SPDT when you need both
A three-terminal SPDT switch gives you NO and NC from the same part, so you can drive a load from one contact and a status input from the other without adding hardware. It also lets you change the logic later by moving one wire.
Common mistakes
- Reading "normally closed" as "the machine is normally running". If the actuator is held down in the installed position, the switch is actuated, not normal.
- Assuming an NC switch is safer by itself. It is only safer if the circuit is designed so that opening the loop stops the hazard.
- Using an NO contact for a safety stop. A cut wire then looks like a released switch and the hazard stays live.
- Mixing up the two when replacing a part without checking continuity first.
자주 묻는 질문
What does "normally" mean on a micro switch?
"Normally" describes the state of the contacts when the actuator is free and no force is applied. It is a property of the switch, not of the machine it is mounted on, so a switch installed in a pre-loaded position is technically actuated even when the equipment is idle.
Is a normally closed micro switch open or closed when powered?
It is closed. Power has no effect on the contact state — only the actuator does. The NC contact conducts until the plunger is pushed past the trip point, at which moment it opens and interrupts the circuit.
Can I convert a normally open switch to normally closed?
Not by wiring. The contact arrangement is fixed by the part. If you need the opposite logic, specify an SPDT part so you can use either contact, or order the SPST version with the contact you need.
Why is a safety interlock wired normally closed?
Because a normally closed loop fails safe. If the wire is cut, a connector pulls out or the switch is damaged, the circuit opens and the machine stops. A normally open loop would look identical to "not actuated" in all of those failure cases.
Does an SPDT micro switch have both NO and NC?
Yes. A single-pole double-throw switch has one common terminal, one normally open contact and one normally closed contact. Only one of the two is connected to common at any moment.
Not sure which contact your design needs?
Tell us what should happen when the mechanism fails or loses power, and our engineers will specify the contact arrangement.